Categories
Victron

Victron Wire Size Chart and Fuse Cheat Sheet (12V, 24V, 48V)

This Victron wire size chart gathers the fuse and cable sizes Victron prints in its own manuals into one page. Use it as a quick reference while you plan, but always check the manual for your exact model, since sizes change between versions. Victron’s general advice is simple: fuse every positive conductor, and size each cable for both its fuse and its run length.

Electrical work can be dangerous: follow the manual, fuse and size every cable correctly, and use a licensed electrician for anything connected to household wiring.

A DC-DC charger wiring video.

Why Voltage Changes Everything

Current equals watts divided by volts. A 2,400W load draws about 200A at 12V, 100A at 24V and 50A at 48V, before inverter losses. Double the voltage and you halve the current, so you can use smaller cable and smaller fuses. That’s why Victron’s 48V inverter/chargers use far thinner battery cable than the 12V versions.

Victron Wire Size Chart: MultiPlus-II 120V

ModelBattery bankDC fuseCable, 0–5m
12/3000/120400–1,200Ah400A2x AWG 1/0
24/3000/70200–700Ah300AAWG 1/0
48/3000/35100–400Ah125AAWG 1
24/5000/120400–1,200Ah400A2x AWG 1/0
48/5000/70200–800Ah200AAWG 2/0

Source: Victron MultiPlus-II 120V manual, installation chapter. Longer runs need thicker cable (see the manual).

SmartSolar MPPT Battery Fuses

ChargerMinimum fuseMaximum fuse
MPPT 100/3035A40A
MPPT 100/5055A70A

Source: Victron BlueSolar/SmartSolar MPPT 100/30 and 100/50 manual.

Victron says to use flexible, multi-stranded copper cable for the battery connection.

Orion XS 12/12-50A DC-DC Charger

ItemValue
External fuse (both ends)60–70A
Cable, under 5m16mm² / 6AWG minimum
Cable, 5–10m4AWG (21.2mm²) minimum
Max terminal size4AWG

Source: Victron Orion XS 12/12-50A manual, “Cable and fuse recommendations.”

Put one fuse near the starter battery and one near the house battery.

Fuse Types by System Voltage

SystemLynx Distributor fuses
12V or 24V36V-rated MEGA fuses
48V58V-rated MEGA fuses

Source: Victron Lynx Distributor manual.

Each Lynx module is rated 1000A. The total of all the fuses shouldn’t exceed the lowest-rated module in the chain.

Rules of Thumb From the Manuals

  • Short and thick: keep battery cables short, and match the positive and negative lengths.
  • Fuse near the source: put the fuse close to the battery.
  • Torque matters: use the torque values in each manual, since loose lugs heat up.
  • Use Wiring Unlimited: Victron’s free book covers voltage drop and cable sizing for long runs.

For the complete spec sheet and current manual, see the Victron MultiPlus-II page.

AWG to mm² Conversion

AWGCross-section (mm²)Nearest metric size
88.410mm²
613.316mm²
421.225mm²
233.635mm²
142.450mm²
1/053.550–70mm²
2/067.470mm²
4/0107.295–120mm²

Victron’s manuals mostly list both sizes. When converting, round up to the next standard metric size, never down.

Quick Current Table

Load12V24V48V
500WAbout 42AAbout 21AAbout 10A
1,000WAbout 83AAbout 42AAbout 21A
2,000WAbout 167AAbout 83AAbout 42A
3,000WAbout 250AAbout 125AAbout 63A

Estimates: watts ÷ volts, before inverter losses. Add 10–15% for inverter efficiency and size for the inverter’s maximum, not your average load.

How Voltage Drop Works

Voltage drop grows with current and cable length. In a 12V system, losing even 0.5V means about 4% of the voltage is gone before it reaches the load. Victron’s Wiring Unlimited book suggests keeping voltage drop low, and its tables show how thick a cable needs to be for a given current and length. A simple estimate:

Voltage drop ≈ current × total loop length × copper resistance ÷ cable cross-section

Copper resistance is about 0.0175 ohm·mm²/m. For 100A over a 4m loop (2m each way) on 35mm², that’s roughly 0.2V (estimate).

Common Fuse Types

Fuse typeTypical use
MEGALynx Distributor and battery outputs
MIDISmaller DC circuits, chargers and MPPTs
ANLInverter and battery feeds
Class TMain battery fuse, especially lithium, for its high interrupt rating
Blade (ATC/ATO)Low-current DC loads such as lights and pumps

Always check the fuse’s voltage rating against the system voltage, especially at 48V.

Worked Example: A Van With a MultiPlus-II 12/3000

  • Battery bank: 400Ah lithium, inside the manual’s 400–1,200Ah range.
  • DC fuse: 400A, per the manual’s table.
  • Battery cable: 2x AWG 1/0 for a run up to 5m.
  • MPPT 100/50: 55–70A fuse, with cable sized to that fuse.
  • Orion XS 12/12-50A: 60–70A fuses at both ends, 6AWG minimum for runs under 5m.

Follow the manual for each device; these are the same figures as in the tables above, pulled together for one build.

Worked Example: A 48V Cabin With a MultiPlus-II 48/5000

  • Battery bank: 400Ah at 48V, inside the manual’s 200–800Ah range.
  • DC fuse: 200A, per the manual’s table.
  • Battery cable: AWG 2/0 for runs up to 5m.
  • Lynx Distributor: 58V-rated MEGA fuses for every output.

Compare that with the 12/3000 van above: the cabin inverter handles more power on half the fuse rating and a single cable.

Planning Checklist

  1. List every device and its maximum current.
  2. Pick each fuse from the device’s manual.
  3. Size each cable for its fuse and its run length.
  4. Keep battery cables short, and match positive and negative.
  5. Check every fuse’s voltage rating against the system voltage.

FAQ

What gauge wire for a Victron MPPT 100/30?

The manual sets a 35–40A battery fuse. Size the cable for that fuse and keep the run short.

Is 48V worth it for wiring alone?

For inverters of 3,000VA and up, it often is. A 48V system draws a quarter of the current of a 12V one.

Should I use tinned copper cable?

Tinned copper resists corrosion, which is why it’s popular on boats and in damp spaces. Whatever you choose, use flexible, multi-stranded copper as Victron recommends.

Do positive and negative cables need the same size?

Yes. The negative cable carries the same current, so size it like the positive and keep the lengths matched.

Sources: Victron MultiPlus-II 120V manual; SmartSolar MPPT 100/30 and 100/50 manual; Orion XS 12/12-50A manual; Lynx Distributor manual (victronenergy.com, accessed Oct 2026).

Related: EcoFlow Delta 3 Max Generator Charging, Allwei 1500W Pure Sine Wave Inverter Review, Klein CL390 Clamp Meter Solar Panel Test, plus the Victron Energy Guide

Leave a Reply