Categories
Guides & Comparisons Victron

Victron MPPT Load Output Explained: What to Connect and BatteryLife

The Victron MPPT load output lets the controller switch DC loads off before the battery is drained, then back on when it recovers. The small SmartSolar charge controllers have a third set of terminals labeled “load” for this. It’s simple, but the settings confuse people. Here’s what each mode does, which models have a physical load output, and what not to connect to it.

A Victron MPPT load output video.

Which Models Have a Load Output?

Victron’s datasheet for the SmartSolar MPPT 75/10, 75/15, 100/15 and 100/20 lists a load output on all four:

ModelBattery voltageMax continuous load current
75/10, 75/15, 100/1512/24V15A
100/20-48V12/24/48V20A (12/24V), 1A (48V)

Source: Victron SmartSolar MPPT 75/10-100/20 datasheet.

On the 48V model, Victron says the load output is meant to drive a relay. Larger controllers have no physical load output, but the MPPT manual describes a virtual load output using the VE.Direct TX cable to control a BatteryProtect or relay.

Victron MPPT Load Output Modes

From the MPPT manual:

  • BatteryLife (default). Self-adapting, aimed at maximizing battery life (see below).
  • Conventional algorithm 1. 12V: off below 11.1V, on above 13.1V. 24V: 22.2V and 26.2V.
  • Conventional algorithm 2. 12V: off below 11.8V, on above 14.0V. 24V: 23.6V and 28.0V.
  • Always off or always on.
  • User defined algorithm 1. Off below Vlow, on above Vhigh.
  • User defined algorithm 2. Off below Vlow or above Vhigh, on in between.

Always on and always off respond immediately. The other modes wait 2 minutes before changing, so a brief inrush current doesn’t trip the output.

BatteryLife Explained

Victron says that if the controller can’t fully recharge the battery each day, a lead-acid battery cycling between partial charge and empty can be destroyed within weeks or months. BatteryLife fixes that. It raises the load-disconnect voltage a little each day until the solar harvest is enough to nearly fill the battery. After that, it modulates the disconnect level so the battery reaches nearly 100% about once a week.

What to Connect

  • Good fits: LED lights, small fans, USB chargers, routers and sensors, within 15A or 20A.
  • Avoid: inverters and anything whose current exceeds the rated load current. Connect large loads straight to the battery through a fuse, and use a BatteryProtect controlled by the virtual load output if you want low-voltage cut-off.

The load output is short-circuit proof, according to Victron.

For the complete spec sheet and current manual, see the Victron SmartSolar MPPT 75/15 page.

Worked Example: Lights and a Fan in a Shed

A shed with a 100Ah lead-acid battery, a SmartSolar 75/15 and 150W of solar runs LED lights (10W) and a small fan (20W) from the load output. At 30W total, that’s about 2.5A, well within the 15A rating (estimate). On a long cloudy stretch, BatteryLife raises the disconnect voltage so the battery isn’t cycled deep day after day, then lowers it again when sunny days return.

Worked Example: A Lithium Battery With a User-Defined Algorithm

A 12V LiFePO4 battery in a small trailer, with a SmartSolar 100/20 powering a router and lights through the load output. Many owners choose a user-defined algorithm for lithium, since BatteryLife is designed around lead-acid behaviour. For example, user-defined algorithm 1 with Vlow at 12.0V and Vhigh at 13.2V switches loads off before the battery is deeply discharged and back on once solar has recovered it (example values; follow your battery maker’s recommended cut-off voltages).

Setting the Load Output in VictronConnect

  1. Open the SmartSolar in VictronConnect and go to Settings → Load output.
  2. Choose the mode: BatteryLife, conventional, user defined, always on or always off.
  3. For user-defined modes, enter Vlow and Vhigh.
  4. Watch the load output state on the main screen to confirm it switches as expected.

The Virtual Load Output for Bigger Loads

Larger SmartSolar models without a physical load output can still control loads through the VE.Direct TX port. With a VE.Direct TX digital output cable connected to a Smart BatteryProtect’s remote input, the controller switches the BatteryProtect on and off using the same load output modes. The BatteryProtect then carries the current, so you can control much larger DC loads.

Load sizeApproach
Up to 15A (12/24V)Physical load output on 75/10, 75/15, 100/15
Up to 20A (12/24V)Physical load output on 100/20
Larger DC loadsVirtual load output plus a BatteryProtect
InvertersDirect to battery, with their own low-voltage cut-off

Street Light Mode

Victron’s SmartSolar controllers also include a street light function that can switch the load output on at dusk and off after a set time or at dawn, based on solar panel voltage. It’s useful for path lights, signage and security lights on a solar-only system.

Wiring Tips

  • Fuse the battery cable close to the battery.
  • Connect the load positive to the load output terminal and the load negative to the battery negative side, as shown in the manual.
  • Use cable sized for the load current and run length.

Checking the Load Output History

VictronConnect’s history shows daily solar yield and the battery’s minimum and maximum voltage. If the load output has switched off on a given day, the minimum voltage tells you how close the battery got to the cut-off. Over a few weeks, that shows whether the system has enough solar for its loads.

BlueSolar Models With a Load Output

The load output isn’t only on SmartSolar. Victron’s BlueSolar MPPT 75/10, 75/15, 100/15 and 100/20 have the same physical load output with the same ratings: 15A on the 10A and 15A models, and 20A on the 100/20 at 12V or 24V (1A at 48V). The modes, BatteryLife and the 2-minute delay all work the same way.

The difference is setup. BlueSolar models have no built-in Bluetooth, so you change the load output settings through the VE.Direct port. Victron lists three ways to connect:

  • A VE.Direct Bluetooth Smart dongle, which adds Bluetooth so VictronConnect works from your phone.
  • A VE.Direct to USB interface for VictronConnect on a laptop.
  • A GX device such as a Cerbo GX, which also shows the load output state in VRM.

See our Victron BlueSolar MPPT review for how the BlueSolar and SmartSolar lines compare.

Load Output or BatteryProtect?

Both switch DC loads off at low battery voltage, so it helps to know which one fits your build:

MPPT load outputBatteryProtect
Current15A or 20A65A, 100A or 220A models
Extra hardwareNoneSeparate unit wired between battery and loads
Works with any chargerNo, part of the small MPPTsYes, standalone
Can be driven by the MPPTBuilt inYes, through the virtual load output
Best forLights, fans, routers, sensorsDC fuse panels, fridges, pumps, larger DC loads

Source: Victron MPPT solar charger manual and BatteryProtect product range.

A simple rule: if all your switched loads add up to less than the load output rating, use the load output and skip the extra part. Once they don’t, wire a BatteryProtect sized for the total and let the MPPT’s virtual load output or its own settings control it. Our Victron Battery Protect wiring and settings guide covers the wiring.

Choosing a Mode by Battery Type

BatteryGood starting modeWhy
Flooded or AGM lead-acidBatteryLife (default)Adjusts the cut-off so the battery reaches nearly full about once a week
Lead-acid, fixed cut-off wantedConventional algorithm 1 or 2Fixed 11.1V/13.1V or 11.8V/14.0V thresholds on 12V
LiFePO4User defined algorithm 1Lets you set Vlow and Vhigh from the battery maker’s figures
Solar lightingStreet light functionSwitches the load at dusk and dawn from panel voltage

Thresholds are from Victron’s MPPT manual. For lithium, use the cut-off voltages your battery maker recommends.

Quick Checklist Before You Wire It

  1. Total load current is within 15A (or 20A on the 100/20).
  2. No inverter on the load output. It goes straight to the battery with its own fuse.
  3. Load output mode chosen in VictronConnect before the loads go on.
  4. Battery fused close to the terminal, with cable sized for the run.
  5. The load output state checked on the VictronConnect main screen after setup.

FAQ

What is the Victron MPPT load output for?

Switching DC loads off at low battery voltage, and on again when it recovers, so you don’t over-discharge the battery.

What’s the default mode?

BatteryLife.

Can I run an inverter from the load output?

Not within the 15A or 20A rating of most inverters’ input current. Wire inverters directly to the battery.

Can I use the load output and the battery terminals at the same time?

Yes. Loads that need low-voltage protection go on the load output, while chargers and larger loads connect to the battery.

Does street light mode need a timer?

No. The controller uses solar panel voltage to detect dusk and dawn, and you set the on-time in VictronConnect.

Does the BlueSolar MPPT have a load output?

Yes. The BlueSolar 75/10, 75/15, 100/15 and 100/20 have the same 15A or 20A load output as the matching SmartSolar models. You set it up through a VE.Direct Bluetooth dongle, a VE.Direct USB interface or a GX device.

Can the load output control a BatteryProtect?

Yes. With a VE.Direct TX digital output cable, the MPPT’s virtual load output switches a BatteryProtect, which then carries the larger current.

Sources: Victron SmartSolar MPPT 75/10, 75/15, 100/15, 100/20 datasheet; BlueSolar MPPT 75/10-100/20 datasheet; BlueSolar and SmartSolar charge controller overview; MPPT solar charger manual (load output, BatteryLife, load output settings), victronenergy.com, accessed Oct 2026.

Related: SunSwift 60A MPPT Solar Charge Controller Review, EcoFlow Delta 3 Max Solar Setup, BougeRV Arch Pro 200W Flexible Solar Panel Review, plus the Victron Energy Guide